Search productSearch post

Explosion-Proof Infrared Gas Analyzer
Explosion-Proof Infrared Gas Analyzer
Explosion-Proof Infrared Gas Analyzer
Explosion-Proof Infrared Gas Analyzer

Explosion-Proof Infrared Gas Analyzer

  • Keywords:infrared gas analyzer, explosion-proof gas analyzer, hazardous environment gas detector
  • Category:CO2 Analysis and Detection

The Explosion‑Proof Infrared Gas Analyzer is a high‑precision detection instrument designed for continuous monitoring of combustible and toxic gases in hazardous industrial environments. Using advanced non‑dispersive infrared (NDIR) technology, it delivers fast, stable, and highly accurate gas concentration measurements while maintaining strong resistance to interference. Its explosion‑proof housing ensures safe operation in areas with flammable gases, vapors, or dust. With long‑term stability, low maintenance requirements, and real‑time alarm functions, this analyzer is widely used in petrochemical plants, gas processing facilities, chemical industries, mining operations, and environmental monitoring applications.

CLICK TO INQUIRE

Product Overview

The Explosion-Proof Infrared Gas Analyzer combines Non-Dispersive Infrared (NDIR) technology with long-life electrochemical sensors to simultaneously measure the volumetric concentration of multiple gases, including CO, CO₂, CH₄, C₃H₈, O₂, and H₂S. Equipped with a front-end gas pre-treatment module, the analyzer effectively handles harsh field conditions with moisture and dust. Its explosion-proof design ensures safe operation in flammable and explosive environments, making it ideal for industrial gas monitoring and safety protection to maintain stable production processes.

Technical Principles

The analyzer uses NDIR technology to measure concentrations of combustible and non-combustible gases (CO, CO₂, CH₄, C₃H₈) by detecting the absorption of infrared light at specific wavelengths. Electrochemical sensors are employed for gases such as O₂ and H₂S, while a dual-channel design enhances signal stability and measurement accuracy. The front-end pre-treatment system removes moisture and particulate matter from the sample gas, ensuring long-term stable sensor operation.

Key Features

  • Explosion-Proof Design: Features flameproof housing and structure capable of withstanding external pressure and preventing flame penetration, suitable for hazardous environments.
  • High-Precision Measurement: Supports multi-component gas detection with no cross-interference; includes self-diagnosis for real-time sensor status monitoring.
  • High Stability: Dual-channel sensor configuration; sample-contact parts made from heat-resistant, corrosion-resistant materials (special stainless steel, PTFE).
  • Automated Pre-Treatment: Front-end gas pre-treatment allows unattended real-time online monitoring, reducing maintenance requirements.
  • Convenient Data Management: Multiple data interfaces for integration with higher-level control systems, enabling real-time data management and analysis.

 

Applications

  • Oil & Gas Industry: Real-time monitoring of hazardous gases during extraction and refining, ensuring operational safety.
  • Chemical Industry: Monitors gas concentrations in chemical reactions to prevent leaks and incomplete reactions.
  • Power Industry: Monitors combustion emissions from power plants to improve efficiency and reduce pollutants.
  • Mining: Ensures worker safety by monitoring gas concentrations in mines and other high-risk environments.
  • Environmental Monitoring: Monitors industrial emissions to ensure compliance with national standards and reduce environmental pollution.
Parameter Description
Measured Components CO, CO2, CH4, C3H8, O2, H2S
Measurement Principle NDIR, ECD
Measurement Range CO/CO2/CH4/C3H8:(0~100)%<br>O2:(0~25)%;H2S:(0~9999)ppm
Linear Error CO/CO2/CH4/C3H8: ±1%F.S.; O2/H2S: ±2%F.S.
Resolution 0.01% (for low range, resolution can reach 1ppm)
Repeatability ≤2%
Response Time T90<60s (NDIR)
Optimal Flow (0.7~1.2)L/min
Inlet Pressure (2~50)kPa
Sample Gas Requirement Dust-free, water-free, oil-free
Communication RS-485/RS-232; 4-20mA; Ethernet
Power Supply AC220V, 50Hz
Display LCD Display
Explosion-proof Rating Ex d ⅡC T6
Features Built-in zeroing pump for automatic air zeroing
Self-diagnosis function, can check sensor status online

 